Panasonic FP7 User Manual page 234

Positioning unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

Specifications
Offset
Name
address
010H
011H
Auxiliary output
012H
mode
Auxiliary output
013H
Delay rate
014H
Pulse output
015H
control code
016H
Startup speed
017H
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
17-42
Default
Set whether to use or not to use the auxiliary output contact and auxiliary
output function of the auxiliary output code whether to be used or unused.
The ON time of the auxiliary output contact is determined by the following
auxiliary output ON time.
bit
Name
1000H
0 to 7
Auxiliary output
mode
15 to 8
Auxiliary output
ON time
When using the delay mode for the auxiliary output, specify the ratio (%)
to output.
0
The setting range is 0(%) to 100(%). If the setting is 50%, the auxiliary
output will be performed when the positioning movement amount exceeds
50%.
Make pulse output, home position, near home, and limit signal settings.
bit
Name
0
Output mode
1
Rotating direction
2
Home logic
30H
3
Near home logic
4
Limit + Logic
5
Limit - Logic
15 to 6
Make startup speed settings for each type of operation.
Make a startup speed change before starting each type of operation.
Setting range: 0 to 32,767,000
Any other settings will be errors.
0
Set the following range according to the unit setting.
Pulse: 1 to 32,767,000 pps
μm: 1 to 32,767,000 μm/s
inch: 0.001 to 32,767.000 inch/s
degree: 0.001 to 32,767.000 rev/s
Setting range and description
Default
Description
0000H: The auxiliary output function
0
(auxiliary output contact or
code) is not used.
0001H: With mode used
0002H: Delay mode used
10
Setting range: 00H (0 ms) to FFH
(255 ms).
Default
Description
0: Pulse/Sign
0
1: CW/CCW
0
0: Count + Direction CW
1: Count + Direction CCW
0
0:Normal Open
1:Normal Close
0
0:Normal Open
1:Normal Close
1
0:Normal Open
1:Normal Close
1
0:Normal Open
1:Normal Close
0