Panasonic FP7 User Manual page 197

Positioning unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

Items
Product no.
Deceleration
stop
Emergency
stop
Limit stop
Error stop
System stop
Software limit
function
Backup
High-speed
counter
function (note
1)
• Limit input CWL, CCWL monitor, and near (DOG) monitor
• Auxiliary output code and auxiliary output contact
Internal current consumption (5 V DC)
External power
supply
Weight
(Note 1): The pulser input function and high-speed counter function use the same pulse input terminal. Therefore,
select either one of them.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
AFP7PP02T
Deceleration
Deceleration time while in operation
time
Deceleration
0 to 10,000 ms (adjustable in 1-ms increments)
time
Deceleration
0 to 10,000 ms (adjustable in 1-ms increments)
time
Deceleration
0 to 10,000 ms (adjustable in 1-ms increments)
time
Deceleration
Immediate stop (0 ms): All axes comes to a stop
time
Pulse: -1,073,741,823 to 1,073,741,823 pulses
μm (0.1 μm): -107,374,182.3 to 107,374,182.3 μm
μm (1 μm): -1,073,741,823 to 1,073,741,823 μm
Setting range
inch (0.00001 inch): -10,737.41823 to 10,737.41823 inches
inch (0.0001 inch): -107,374.1823 to 107,374.1823 inches
degree (0.1 degree): -107,374,182.3 to 107,374,182.3 degrees
degree (1 degree): -1,073,741,823 to 1,073,741,823 degrees
Parameters and positioning data are saved in flash memories
(with no batteries)
Counting
Counting range -2,147,483,648 to 2,147,483,648 pulses
range
Phase difference input, direction discrimination input, and individual
Input mode
input (with multiplier function for each mode)
300 mA or less
Voltage
21.6 to 26.4 V DC
Current
50 mA
consumption
Approx. 130 g
Description
2-axis type
AFP7PP02L
300 mA or less
90 mA
Approx. 150 g
17.1 Specifications
4-axis type
AFP7PP04T
AFP7PP04L
300 mA or less
300 mA or less
50 mA
90 mA
Approx. 130 g
Approx. 150 g
17-5