Automatic Operation (Synchronous Control)
 Cam pattern specifications
The following specifications of cam patterns can be set.
Setting items
Resolution
No. of cam patterns
Section setting
Displacement setting
Cam curve
Adjustment function
Shift function
Indication

8.5.2 Types and Contents of Setting Parameters

The use of the electronic cam requires the following parameter settings.
Parameter name
Electronic cam
use/non-use
Cam pattern
Cam control master
axis period
Cam pattern number
to use
Cam stroke
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
8-16
1024, 2048, 4096, 8192, 16384, 32768
Resolutions of 1024, 2048, and 4096: 16
Resolution of 8192: 8
Resolution of 16384: 4
Resolution of 32768: 2
100%/cycle, 20 sections max.
100% setting
Selected from the following ones
Uniform velocity/Constant acceleration/Simple harmonic motion/Cycloid/Modified
trapezoid/Modified sine/Trapecloid
One-dwell cycloidal m=1/One-dwell cycloidal m=2/3/One-dwell modified trapezoid
m=2/3/One-dwell modified trapezoidal (Ferguson)/One-dwell modified sine/One-dwell
trapecloid/No-dwell modified trapezoid/NC2 curve/Asymmetric cycloid/Asymmetric
modified trapezoid
Function to adjust the displacement of desired point data.
1,000 points max. (in units of cam data)
Phase shift in created cam data
0% to 100%
Displacement/Speed/Acceleration/Jerk
A check box allows desired display.
Select the use or non-use of the electronic cam function.
When the electronic cam is not used, the electronic cam function will not work, and
output from the electronic clutch will be output as pulses.
The cam pattern is the most fundamental setting for using the electronic cam function.
The cam pattern is set in the cam pattern settings window in the FPWIN GR7
Configuration screen.
The positioning unit converts cam patterns into point data based on the preset cam
curves and resolutions.
Set the number of pulses corresponding to the total phase of the cam pattern used
(one-rotation data on the master axis).
Specify the cam pattern number to be used from cam patterns created.
Set the number of pulses corresponding to the total displacement (100%) of the cam
pattern to use.