Setting And Operation Of Jog Operation - Panasonic FP7 User Manual

Positioning unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

Manual Operation
(JOG Operation)

9.1 Setting and Operation of JOG Operation

The example below is a case of the positioning unit installed in the slot 1. Settings are made
in pulses.
 Settings
Parameters required for the JOG operation of the positioning unit is set in the positioning
setting menu of the programming tool.
Items
Acceleration/deceleration pattern
Acceleration time (ms)
Deceleration time (ms)
Target speed
 Operation diagram
f [pps]
10000
Forward JOG contact Y120
Reverse JOG contact Y121
BUSY flag X118
Operation done flag X120
 Operation of each contact
• The BUSY flag (X118), which indicates that the motor is running, will turn ON when the
positioning control starts, and it will turn OFF when the operation completes.
• The operation done flag (X120), which indicates the completion of operation, will turn ON
when the current operation is completed, and it will be held until the next positioning control,
JOG operation, home return, or pulser operation starts.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
9-2
0: Linear acceleration/deceleration
100 ms
100 ms
10000 pps
Forward
100
100
Setting example
Reverse
100
100
t [ms]

Advertisement

Table of Contents
loading

Table of Contents