Types And Contents Of Setting Parameters - Panasonic FP7 User Manual

Positioning unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

Automatic Operation (Synchronous Control)

8.4.2 Types and Contents of Setting Parameters

The use of the electronic clutch requires the following parameter settings.
Parameter name
Electronic clutch used/unused
Trigger type
Edge selection
Clutch
ON
Method
Slip time
Trigger type
Edge selection
Clutch
OFF
Method
Slip time
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
8-12
Set to use or not to use the electronic clutch function.
The electronic clutch is by default disengaged.
Be sure to engage the electronic clutch in response to the operation.
The electronic clutch will be always engaged when the electronic clutch is
not in use, in which case, output data from the electronic gear will be input
as it is into the electronic cam. At that time, the master axis will always
operate in synchronization with the slave axes.
Set an I/O clutch ON request as a trigger to be detected.
Select the method of trigger signal detection from "Level," "Rising edge," or
"Falling edge."
Select "Direct" or "Slip" for the engagement of the clutch.
If "Slip" is selected, set the slip time.
Set an I/O clutch OFF request as a trigger to be detected.
Select the method of trigger signal detection from "Level," "Rising edge," or
"Falling edge."
Select "Direct" or "Slip" for the engagement of the clutch.
If "Slip" is selected, set the slip time.
Outline

Advertisement

Table of Contents
loading

Table of Contents