Manual Operation
(Pulser Operation)

11.1 Setting and Operation of Pulser Operation

 Types of Pulser Operation
Pulser operation is a function that uses a pulser connected to the positioning unit to output
pulses manually.
The following pulser operation methods are available.
Operation
method
Obtains the number of pulser pulses in 1-ms units and operates.
Standard
operation
Reflects the content of pulse input directly in the actual operation of the positioning unit.
Speed limits
When the speed of pulse input exceeds the preset maximum speed, the operation will continue
with the maximum speed maintained.
(pulses hold)
The number of pulser pulses input will be maintained. Therefore, pulses not output will be
maintained. Therefore, pulses may be output even if there is no pulser input.
Speed unit is "Set unit x 1000/s".
Speed limits
When the speed of pulse input exceeds the preset maximum speed, the operation will continue
with the maximum speed maintained.
(Truncate)
Pulses are output in synchronization with the operation of the pulser while pulses not output
are discarded.
Speed unit is "Set unit x 1000/s".
The example below is a case of the positioning unit installed in the slot 1. Settings are made
in pulses.