Panasonic FP7 User Manual page 68

Positioning unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

Transfer to Unit and Commissioning
 Monitor items
Items
Table number executing
Auxiliary output code
Current value (pulse)
Unit conversion current value
Pulse input value
Deviation
Axis state
Error code
Error clear
Warning code
Warning clear
If a recoverable error occurs in the positioning unit, click the [Error clear]
button to clear the error.
If a warning occurs in the positioning unit, click [Warning clear] to clear the
warning.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
6-6
Description
The table number that the positioning data is being executed or has been
executed.
Auxiliary output code
The current value of the positioning unit.
The unit-converted current value of the positioning unit.
Monitors the input pulse value.
Displays the deviation of the amount of movement while the auto check
function for the amount of movement is activated.
The operating states of axes or error and warning occurrences.
The latest error code if an error occurs.
Clears the error by clicking this button if an error occurs.
Indicates the latest warning code if a warning occurs.
Clears the warning by clicking this button if a warning occurs.

Advertisement

Table of Contents
loading

Table of Contents