Automatic Operation (Positioning Control)

7.3 Setting and Operation of Positioning Repeat Function

The positioning repeat function enables continuous positioning control according to the
number of repetitions specified.
The number of repetitions is set in the area for the number of positioning repetitions on each
axis. The number of repetitions can be set within a range of 2 to 254. It is possible to specify a
limitless number of repetitions by setting 255 for the area of the number of positioning
repetitions.
 Outline of Positioning Repeat Function
The positioning unit operates as shown below in the case of repeating positioning control
three times.
If a dwell time of 0 is set for E-point control, i.e., the end point of positioning control, the
positioning unit will perform E-point control as P-point control, and complete positioning
control after repeating positioning control three times continuously.
If the dwell time is set to a value other than 0 for E-point control, i.e., the end point of
positioning control, the positioning unit will perform E-point control as C-point control, and
repeat positioning control with a pause specified by the dwell time (ms).
The positioning unit will finish operating after repeating positioning control three times.