Specifications
 Clutch setting area
Offset
address
020H
Clutch ON trigger types
021H
Clutch ON edge selection
028H
Clutch OFF trigger types
029H
Clutch OFF edge selection
030H
Clutch ON method
032H
Clutch ON slip method
033H
Clutch ON slip time
036H
Clutch ON slip curve selection
040H
Clutch OFF method
042H
Clutch OFF slip method
043H
Clutch OFF slip time
046H
Clutch OFF slip curve selection
 Electronic cam setting area
Offset
address
050H
Cam control
- 051H
synchronous master axis cycle
053H
Cam pattern number used
054H
Cam stroke amount
- 055H
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
17-70
Name
Default
00H
00H
00H
00H
00H
00H
1
00H
00H
00H
1
00H
Name
Default
1
1
1
Description
00H: I/O clutch ON request
Set enabled conditions for the trigger signal.
00H: Level
01H: Rising edge
02H: Falling edge
00H: I/O clutch OFF request
Set enabled conditions for the trigger signal.
00H: Level
01H: Rising edge
02H: Falling edge
00H: Direct
01H: Slip
00H: Slip time setting
1 to 10000 ms
00H: Linear
00H: Direct
01H: Slip
00H: Slip time setting
1 to 10000 ms
00H: Linear
Description
Settings for cam control synchronous master cycle
1 to 2,147,483,647
Registered cam pattern number for use
1 to (16)
Displacement upper limit settings for cam control
1 to 2,147,483,647