Panasonic FP7 User Manual page 237

Positioning unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

Offset
address
026H
Home return creep
speed
027H
Deviation counter
028H
clear signal ON time
JOG operation
029H
setting code
JOG operation
02AH
acceleration time
JOG operation
02BH
deceleration time
02CH
JOG operation target
speed
02DH
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
17.6 Details of Each Axis Setting Area in Unit Memory
Name
Default
100
1
0H
100
1,000
Setting range and description
Set the speed to search the home position after near home input.
Set a speed lower than the target home return speed.
Setting range: 1 to 32,767,000
Any other settings will be errors.
Set the following range according to the unit setting.
Pulse: 1 to 32,767,000 pps
μm: 1 to 32,767,000 μm/s
inch: 0.001 to 32,767.000 inch/s
degree: 0.001 to 32,767.000 rev/s
Set the ON time of the deviation counter clear signal after home return
completion.
Setting range: 1 to 100 ms
The deviation counter clear signal is set to 100 ms even if a setting in
excess of 100 ms is made.
Sets the operation mode of the JOG operation.
bit
Name
0
1
Acceleration /
Deceleration
pattern settings
2 to 15
Sets the acceleration/deceleration time for JOG operation.
When JOG operation starts, the positioning unit will go into
acceleration operation in the preset time. After the start contact of
JOG operation is ON, the positioning unit will go into deceleration
operation in the preset time to come to a stop.
Setting range: 0 to 10,000 (ms)
Any other settings will be errors.
Set the target speed for JOG operation.
After the start of the JOG operation of the positioning unit, the
positioning unit will accelerate to move to the target speed while the
start contact of the JOG operation is ON.
The positioning unit will operate at target speed after the target speed
is reached.
Setting range: 0 to 32,767,000
Any other settings will be errors.
Set the following range according to the unit setting.
Pulse: 1 to 32,767,000 pps
μm: 1 to 32,767,000 μm/s
inch: 0.001 to 32,767.000 inch/s
degree: 0.001 to 32,767.000 rev/s
Default
Description
0: Linear
0
acceleration/deceleration
1: S-shaped
acceleration/deceleration
17-45

Advertisement

Table of Contents
loading

Table of Contents