17.4.10 Pulse Count Control Area

Makes input pulse changes if high-speed pulses are set for pulse input.
Unit
memory no.
Name
(Hex)
Pulse count
UM 00240
enable flag
Pulse count
UM 00241
value change
request flag
UM 00248
Pulse input
changed value of
UM 00249
1st axis
UM 0024A
Pulse input
changed value of
UM 0024B
2nd axis
UM 0024C
Pulse input
changed value of
UM 0024D
3rd axis
UM 0024E
Pulse input
changed value of
UM 0024F
4th axis
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
17-28
The pulse input will be counted when the corresponding bit for each axis is set to 0.
This flag will be enabled only if the pulse input application is set to high-speed counter.
bit
Name
0
1st axis pulse count enabled
1
2nd axis pulse count enabled
2
3rd axis pulse count enabled
3
4th axis pulse count enabled
4
5
6
7
15 to 8
The pulse input value will be changed to the set pulse count when the
corresponding bit for each axis is set to 1 from 0.
This flag is an edge trigger. Be sure to change the flat to 0 from 1 at the time of the
change.
bit
Name
0
1st axis pulse count change
1
2nd axis pulse count change
2
3rd axis pulse count change
3
4th axis pulse count change
4
5
6
7
15 to 8
Set the desired pulse input value to replace the current value for each axis.
Description
Default
Description
0: Pulse input count enabled
0
1: Pulse input count disabled
0
0
0
Default
Description
0:
0
Pulse input count change disabled
0
0→1:
0
Pulse input count change enabled
0