Mitsubishi MELSEC-L series Programming Manual page 72

Hide thumbs Also See for MELSEC-L series:
Table of Contents

Advertisement

G_OGLOAD
(17) Q68RD3-G
Device
System area
[0]
s
Completion status
[1]
s
[2]
s
System area
[3]
s
CH1 Factory default offset value
[4]
s
CH1 Factory default gain value
[5]
s
CH1 User range settings offset value
[6]
s
CH1 User range settings gain value
[7]
s
CH1 User range settings resistance offset value (L)
[8]
s
CH1 User range settings resistance offset value (H)
[9]
s
CH1 User range settings resistance gain value (L)
[10]
s
CH1 User range settings resistance gain value (H)
[11]
s
CH2 Factory default offset value
[12]
s
CH2 Factory default gain value
[13]
s
CH2 User range settings offset value
[14]
s
CH2 User range settings gain value
[15]
s
CH2 User range settings resistance offset value (L)
[16]
s
CH2 User range settings resistance offset value (H)
[17]
s
CH2 User range settings resistance gain value (L)
[18]
s
CH2 User range settings resistance gain value (H)
[19]
s
CH3 Factory default offset value
[20]
s
CH3 Factory default gain value
[21]
s
CH3 User range settings offset value
[22]
s
CH3 User range settings gain value
[23]
s
CH3 User range settings resistance offset value (L)
[24]
s
CH3 User range settings resistance offset value (H)
[25]
s
CH3 User range settings resistance gain value (L)
[26]
s
CH3 User range settings resistance gain value (H)
[27]
s
CH4 Factory default offset value
[28]
s
CH4 Factory default gain value
[29]
s
CH4 User range settings offset value
[30]
s
CH4 User range settings gain value
[31]
s
CH4 User range settings resistance offset value (L)
[32]
s
CH4 User range settings resistance offset value (H)
[33]
s
CH4 User range settings resistance gain value (L)
[34]
s
CH4 User range settings resistance gain value (H)
[35]
s
CH5 Factory default offset value
[36]
s
CH5 Factory default gain value
[37]
s
CH5 User range settings offset value
[38]
s
CH5 User range settings gain value
[39]
s
CH5 User range settings resistance offset value (L)
[40]
s
CH5 User range settings resistance offset value (H)
[41]
s
5.1 Analog Instruction
5-26
5.1.2 OGLOAD instruction
Control data of Q68RD3-G (1/2)
Item
The instruction completion status is stored.
0
Other than 0
Setting data
Setting range
:Normal completion
:Error completion
(error code)
Setting side
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-q series

Table of Contents