ZP_BUFSND
5.4.19

BUFSND instruction

ZP_BUFSND
Structured ladder
ZP_BUFSND
EN
ENO
Un*
s1
s2
s3
Input argument
EN:
Un*:
s1:
s2:
s3:
Output argument
ENO:
d1:
Function
This instruction reads receive data from external device in fixed buffer communication.
This instruction is used in a main program.
5.4 CC-Link IE Controller Network, MELSECNET/H, and Ethernet Instruction
5-208
5.4.19 BUFSND instruction
ST
ENO:=
(EN, Un*, s1, s2, s3, d1);
ZP_BUFSND
d1
Executing condition
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/O number in
three digits)
Connection number (1 to 16)
Variable that stores control data
Start number of the device that stores write data
Execution result
Variable that turns ON upon completion of the instruction
d[1] also turns ON at the time of error completion.
Internal device
Setting
*1
data
Bit
Word
s1
s2
s3
d1
Executing condition
ZP_BUFSND
:Bit
:String
:ANY16
:Array of ANY16 [0..1]
:ANY16
:Bit
:Array of bit [0..1]
J
\
R, ZR
U
Bit
Word
*1: Local devices and file registers per program cannot be used as setting data.
ZP_BUFSND
E71
:
indicates the following instruction.
Constant
Zn
Others
\G