8.1.7

IPSTOP instruction

IPSTOP1
IPSTOP2
Structured ladder
IPSTOP
EN
ENO
Input argument
EN:
Executing condition
Output argument
ENO:
Execution result
Setting
data
Function
This instruction stops the positioning of the specified axis (refer to the following).
• IPSTOP1: Axis 1
• IPSTOP2: Axis 2
Program Example
The following program stops the axis 1 when M0 turns ON.
[Structured ladder]
[ST]
IPSTOP1(M0);
ST
ENO:=
(EN);
IPSTOP
Internal device
R, ZR
Bit
Word
Bit
8.1 Positioning Function Dedicated Instruction
IPSTOP1, IPSTOP2
IPSTOP1, IPSTOP2
indicates any of the following
instructions.
IPSTOP1
IPSTOP2
:Bit
:Bit
J
\
Zn
U
\G
Word
8.1.7 IPSTOP instruction
8
L CPU
Constant
Others
8-13