Z_BUFRCVS
5.4.18

BUFRCVS instruction

Z_BUFRCVS
Structured ladder
Z_BUFRCVS
EN
ENO
Un*
s
Input argument
EN:
Un*:
s:
Output argument
ENO:
d:
5.4 CC-Link IE Controller Network, MELSECNET/H, and Ethernet Instruction
5-206
5.4.18 BUFRCVS instruction
ST
ENO:=
(EN, Un*, s, d);
Z_BUFRCVS
d
Executing condition
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/O number in
three digits)
Connection number (1 to 16)
Execution result
Start number of the device that stores read data
Internal device
Setting
*1
data
Bit
Word
s
d
Z_BUFRCVS
:Bit
:String
:ANY16
:Bit
:ANY16
J
\
R, ZR
U
Bit
Word
*1: Local devices and file registers per program cannot be used as setting data.
Z_BUFRCVS
E71
indicates the following instruction.
Constant
Zn
Others
\G
K, H