Mitsubishi MELSEC-L series Programming Manual page 117

Hide thumbs Also See for MELSEC-L series:
Table of Contents

Advertisement

Control Data
Device
Item
Transmission channel
[0]
s1
Transmission result
[1]
s1
Number of send data
[2]
s1
Program Example
The following program sends desired data stored in devices from D11 to D15 using the
bidirectional protocol.
(For the Q series C24 whose I/O signals are X/Y00 to X/Y1F)
[Structured ladder]
Setting data
Set the transmission channel.
1: Channel 1 (CH1 side)
2: Channel 2 (CH2 side)
The instruction completion status is stored.
0
: Normal completion
Other than 0
: Error completion (error code)
Set the number of send data.
5.2 Serial Communication and Modem Interface Instruction
G_BIDOUT
Setting range
1, 2
1 or more
Transmission
instruction pulse
Sets transmission
channel to 1
Sets number of send
data to 5 words
Sends data
Turns normal completion
flag ON
Stores error code
Turns error completion
flag ON
Turns normal completion
flag OFF
Turns error completion
flag OFF
5.2.4 BIDOUT instruction