Uini Instruction - Mitsubishi MELSEC-L series Programming Manual

Hide thumbs Also See for MELSEC-L series:
Table of Contents

Advertisement

Z_UINI
5.4.22

UINI instruction

Z(P)_UINI
Structured ladder
Z_UINI
EN
ENO
Un*
s
Input argument
EN:
Un*:
s:
Output argument
ENO:
d:
Function
Ethernet: This instruction reinitializes the Ethernet module.
CC-Link IE controller network: This instruction sets the station number of the CC-Link IE
controller network module on host station.
5.4 CC-Link IE Controller Network, MELSECNET/H, and Ethernet Instruction
5-218
5.4.22 UINI instruction
ST
ENO:=
(EN, Un*, s, d);
Z_UINI
d
Executing condition
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/O number in
three digits)
Variable that stores control data
Execution result
Variable that turns ON upon completion of the instruction
d[1] also turns ON at the time of error completion.
Internal device
Setting
*1
data
Bit
Word
s
d
P: Executing condition
instructions.
Z_UINI
:Bit
:String
:Array of ANY16 [0..5]
:Bit
:Array of bit [0..1]
J
\
R, ZR
U
Bit
Word
*1: Local devices and file registers per program cannot be used as setting data.
Z_UINI
CC IE
E71
:
indicates any of the following
ZP_UINI
Zn
Constant Others