Mitsubishi MELSEC-L series Programming Manual page 342

Hide thumbs Also See for MELSEC-L series:
Table of Contents

Advertisement

SP_SOCCSET
Control Data
Device
Item
System area
[0]
s2
Completion status
[1]
s2
[2]
s2
Destination IP address
[3]
s2
Destination port No.
[4]
s2
Precautions
Use the Built-in Ethernet port QCPU of which the function version is B or later and the first five
digits of the serial number are '11012' or higher.
7.7 SOCCSET Instruction
7-20
Setting data
The instruction application status is stored.
0
: Normal completion
Other than 0
: Error completion (error code)
Specify the IP address of the external device.
Specify the port number of the external device.
Setting range
Setting side
System
1
to
H
FFFFFFFF
H
0
: No
H
User
destination
(FFFFFFFF
:
H
broadcast)
1
to FFFF
H
H
(FFFF
:
User
H
broadcast)