Mitsubishi MELSEC-L series Programming Manual page 82

Hide thumbs Also See for MELSEC-L series:
Table of Contents

Advertisement

G_OGSTOR
(5) Q62AD-DGH
Device
System area
[0]
s
Completion status
[1]
s
[2]
s
System area
[3]
s
CH1 Industrial shipment settings offset value (L)
[4]
s
CH1 Industrial shipment settings offset value (H)
[5]
s
CH1 Industrial shipment settings gain value (L)
[6]
s
CH1 Industrial shipment settings gain value (H)
[7]
s
CH2 Industrial shipment settings offset value (L)
[8]
s
CH2 Industrial shipment settings offset value (H)
[9]
s
CH2 Industrial shipment settings gain value (L)
[10]
s
CH2 Industrial shipment settings gain value (H)
[11]
s
[12]
s
to
System area
[19]
s
CH1 User range settings offset value (L)
[20]
s
CH1 User range settings offset value (H)
[21]
s
CH1 User range settings gain value (L)
[22]
s
CH1 User range settings gain value (H)
[23]
s
CH2 User range settings offset value (L)
[24]
s
CH2 User range settings offset value (H)
[25]
s
CH2 User range settings gain value (L)
[26]
s
CH2 User range settings gain value (H)
[27]
s
[28]
s
to
System area
[35]
s
5.1 Analog Instruction
5-36
5.1.3 OGSTOR instruction
Item
The instruction completion status is stored.
0
Other than 0
Setting data
: Normal completion
: Error completion (error code)
Setting range
Setting side
System
System
System
System
System
System
System
System
System

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-q series

Table of Contents