5.4.7

RECVS instruction

Z_RECVS
Structured ladder
Z_RECVS
EN
ENO
Un*
d1
s
d2
Input argument
EN:
Executing condition
Un*:
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/O number in
three digits)
s:
Variable that stores control data
Output argument
ENO:
Execution result
d1:
Start number of the host station's device that stores read data :ANY16
d2:
Dummy
Setting
data
Function
This instruction reads received data.
5.4 CC-Link IE Controller Network, MELSECNET/H, and Ethernet Instruction
ST
ENO:=
(EN, Un*, s, d1, d2);
Z_RECVS
Internal device
R, ZR
*1
Bit
Word
s
d1
d2
*1: Local devices and file registers per program cannot be used as setting data.
CC IE
indicates the following instruction.