Device
4-wire CH1 Factory default offset value (L)
[16]
s
4-wire CH1 Factory default offset value (H)
[17]
s
4-wire CH1 Factory default gain value (L)
[18]
s
4-wire CH1 Factory default gain value (H)
[19]
Q64RD
s
-G
4-wire CH1 User range settings offset value (L)
[20]
s
4-wire CH1 User range settings offset value (H)
[21]
s
4-wire CH1 User range settings gain value (L)
[22]
s
4-wire CH1 User range settings gain value (H)
[23]
s
4-wire CH1 User range settings resistance offset value (L)
[24]
s
4-wire CH1 User range settings resistance offset value (H)
[25]
s
4-wire CH1 User range settings resistance gain value (L)
[26]
s
4-wire CH1 User range settings resistance gain value (H)
[27]
s
3-wire CH2 Factory default offset value
[28]
s
3-wire CH2 Factory default offset value
[29]
s
3-wire CH2 Factory default gain value
[30]
s
3-wire CH2 Factory default gain value
[31]
s
Q64RD
3-wire CH2 User range settings offset value
[32]
s
3-wire CH2 User range settings offset value
[33]
s
3-wire CH2 User range settings gain value
[34]
s
3-wire CH2 User range settings gain value
[35]
s
3-wire CH2 Factory default offset value (L)
[28]
s
3-wire CH2 Factory default offset value (H)
[29]
s
3-wire CH2 Factory default gain value (L)
[30]
s
3-wire CH2 Factory default gain value (H)
[31]
Q64RD
s
-G
3-wire CH2 User range settings offset value (L)
[32]
s
3-wire CH2 User range settings offset value (H)
[33]
s
3-wire CH2 User range settings gain value (L)
[34]
s
3-wire CH2 User range settings gain value (H)
[35]
s
3-wire CH2 User range settings resistance offset value (L)
[36]
s
3-wire CH2 User range settings resistance offset value (H)
[37]
s
3-wire CH2 User range settings resistance gain value (L)
[38]
s
3-wire CH2 User range settings resistance gain value (H)
[39]
s
4-wire CH2 Factory default offset value
[40]
s
4-wire CH2 Factory default offset value
[41]
s
4-wire CH2 Factory default gain value
[42]
s
4-wire CH2 Factory default gain value
[43]
s
Q64RD
4-wire CH2 User range settings offset value
[44]
s
4-wire CH2 User range settings offset value
[45]
s
4-wire CH2 User range settings gain value
[46]
s
4-wire CH2 User range settings gain value
[47]
s
Control data of Q64RD/Q64RD-G (2/5)
Item
G_OGLOAD
Setting
Setting data
range
5.1 Analog Instruction
5.1.2 OGLOAD instruction
Setting
side
System
System
System
System
System
System
System
System
System
System
System
System
System
5
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
5-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-q series

Table of Contents