G_RISEND
5.3.4

RISEND instruction

G(P)_RISEND
Structured ladder
G_RISEND
EN
ENO
Un*
d1
s1
d2
s2
Input argument
EN:
Un*:
s1:
s2:
Output argument
ENO:
d1:
d2:
Function
This instruction automatically performs handshaking with an intelligent device station and writes
data to the buffer memory of the specified intelligent device station.
This instruction is applicable with a module having a handshake signal, such as the
AJ65BT-R2(N).
5.3 CC-Link Instruction
5-122
5.3.4 RISEND instruction
ST
ENO:=
(EN, Un*, s1, s2, d1, d2);
G_RISEND
Executing condition
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/O number in
three digits)
Variable that stores control data
Variable that stores interlock signal
Execution result
Start number of the device that stores write data
Variable that turns ON upon completion of the instruction
d2[1] also turns ON at the time of error completion.
Internal device
Setting
R, ZR
*1
data
Bit
Word
s1
s2
d1
d2
P: Executing condition
instructions.
G_RISEND
GP_RISEND
:Bit
:ANY16
:Array of ANY16 [0..4]
:Array of ANY16 [0..2]
:Bit
:ANY16
:Array of bit [0..1]
J
\
U
Bit
Word
*1: Local devices and file registers per program cannot be used as setting data.
G_RISEND
:
indicates any of the following
Zn
Constant Others