19.11 Setting Up Data Interfaces; Serial Interfaces On The Tnc 620; Application; Setting The Rs-232 Interface - HEIDENHAIN TNC 620 User Manual

Cnc
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

MOD Functions | Setting up data interfaces

19.11 Setting up data interfaces

Serial interfaces on the TNC 620

The TNC 620 automatically uses the LSV2 transmission protocol
for serial data transfer. The LSV2 protocol is prescribed and cannot
be modified apart from setting the baud rate (machine parameter
baudRateLsv2, no. 106606). You can also define another type of
data transfer (interface). The settings described below are therefore
effective only for the respective newly defined interface.

Application

To set up a data interface, press the MOD key. Enter the code
number 123. In the CfgSerialInterface (no. 106700) machine
parameter, you can enter the following settings:

Setting the RS-232 interface

Open the RS232 folder. The control then displays the following
settings:
Set BAUD RATE
(baud rate no. 106701)
You can set the BAUD RATE (data transfer speed) from 110 to 115
200 baud.
HEIDENHAIN | TNC 620 | Conversational Programming User's Manual | 10/2017