Setting
Release USB mass memory
Calculator
User name
Password
Windows domain:
Max. waiting time (seconds):
Force
Restart
Run during restart
Run during switch-off
Entries in the Advanced
options area

Starting and stopping the connection

Once a connection has been configured, it is shown as an icon in
the Remote Desktop Manager window. Click the connection icon
with the right mouse key to open a menu in which the display can
be started and stopped.
Use the right DIADUR key on the keyboard to change to the third
desktop and back to the control interface. You can also use the task
bar to get to this desktop.
If the desktop of the external connection or the external computer
is active, all inputs from the mouse and the keyboard are
transmitted there.
When the HEROS 5 operating system is shut down, all
connections are canceled automatically. Please note, however, that
only the connection is canceled, whereas the external computer or
the external system is not shut down automatically.
Further information:
computer", page 119
120
Meaning
Not advisable with this connection
Host name or IP address of the external computer. In the recom-
mended configuration of the IPC 6641, the IP address 192.168.254.3
is used
User name with which the connection should be logged on
Password for connecting to the VNC server
Domain of the target computer, if required
When the control shuts down, it commands the Windows comput-
er to shut down. Before the control displays the message You may
switch off now, it waits for <Timeout> seconds. If the Windows
computer is switched off before the <Timeout> seconds have
expired, the control stops waiting.
If Force is not selected, Windows waits up to 20 seconds. This
delays the shutdown process or the Windows computer is switched
off before Windows has shut down.
Reboot the Windows computer.
Reboot the Windows computer when the control reboots. Effective
only if the control is rebooted using the shutdown icon at the bottom
right in the taskbar or if a reboot is initiated as a result of a change in
the system settings (e.g. network settings).
The Windows computer is switched off when the control is shut
down (no reboot). This is the standard scenario. The END key will
then no longer trigger a reboot, either.
Available only to authorized specialists
"Shutting down or rebooting an external
Introduction | Remote Desktop Manager (option 133)
HEIDENHAIN | TNC 620 | Conversational Programming User's Manual | 10/2017
Input
Required
Required
Required
Optional
Required
Required
Required
Required
Required
Optional

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 620 eTnc 620 programming station

Table of Contents