H1-oo
Function
Setting
71
Speed/Torque control Sswitch
72
Zero servo
75
Up 2 command
76
Down 2 command
77
ASR gain switch
External torque reference polarity
78
inversion
Forward/reverse detection
7E
(V/f Control with Simple PG
feedback)
DriveWorksEZ
90 to 97
digital inputs 1 to 8
9F
DriveWorksEZ disable
u

H2: Multi-Function Digital Outputs

No.
(Addr.
Name
Hex)
H2-01
Terminal M1-M2 function
(40B)
selection (relay)
H2-02
Terminal P1-PC function
(40C)
selection (photocoupler)
H2-03
Terminal P2-PC function
(40D)
selection (photocoupler)
H2-06
Watt Hour Output Unit
(437)
Selection
YASKAWA ELECTRIC SIEP YEAHHP 01B YASKAWA AC Drive – A1000 HHP Programming Manual
H1 Multi-Function Digital Input Selections
V/f
V/f w PG
OLV/PM
AOLV/PM
Open: Speed Control
Closed: Torque Control
V/f
V/f w PG
OLV/PM
AOLV/PM
Closed: Zero Servo enabled
All Modes
Used to control the bias added to the frequency reference by the Up/Down 2 function. The
Up 2 and Down 2 commands must always be used in conjunction with one another.
All Modes
Used to control the bias added to the frequency reference by the Up/Down 2 function. The
Up 2 and Down 2 commands must always be used in conjunction with one another.
V/f
V/f w PG
OLV/PM
AOLV/PM
AOLV/PM
Open: ASR proportional gain 1 (C5-01)
Closed: ASR proportional gain 2 (C5-03)
V/f
V/f w PG
OLV/PM
AOLV/PM
Open: Forward torque reference.
Closed: Reverse polarity.
V/f
V/f w PG
V/f w PG
OLV/PM
AOLV/PM
Direction of rotation detection (for V/f with Simple PG Feedback)
All Modes
Reserved for DWEZ input functions
All Modes
Open: DWEZ enabled
Closed: DWEZ disabled
Description
All Modes
Refer to H2 Multi-Function Digital Output Settings on pages
descriptions of setting values.
All Modes
Outputs a 200 ms pulse signal when the watt-hour counter increases by the
units selected.
0: 0.1 kWh units
1: 1 kWh units
2: 10 kWh units
3: 100 kWh units
4: 1000 kWh units
A.9 H Parameters: Multi-Function Terminals
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV
CLV/PM
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
274
Values
Default: 0
Range: 0 to 192
to
276
for
Default: 1
Range: 0 to 192
Default: 2
Range: 0 to 192
Default: 0
Range: 0 to 4