A.9 H Parameters: Multi-Function Terminals
H2-oo
Function
Setting
3C
LOCAL/REMOTE status
3D
During speed search
3E
PID feedback low
3F
PID feedback high
4A
During KEB Ride-Thru
4C
During fast stop
4D
oH Pre-alarm time limit
60
Internal cooling fan alarm
DriveWorksEZ
90 to 92
digital outputs 1 to 3
Function 0 to 92 with inverse
100 to 192
output
u

H3: Multi-Function Analog Inputs

No.
(Addr.
Name
Hex)
H3-01
Terminal A1 Signal Level
(410)
Selection
H3-02
Terminal A1 Function
(434)
Selection
H3-03
(411)
Terminal A1 Gain Setting
H3-04
(412)
Terminal A1 Bias Setting
H3-05
Terminal A3 Signal Level
(413)
Selection
H3-06
Terminal A3 Function
(414)
Selection
H3-07
(415)
Terminal A3 Gain Setting
H3-08
(416)
Terminal A3 Bias Setting
276
H2 Multi-Function Digital Output Settings
All Modes
Open: REMOTE
Closed: LOCAL
V/f
V/f w PG
OLV
OLV/PM
AOLV/PM
CLV/PM
Closed: Speed Search is being executed.
All Modes
Closed: PID feedback level is too low.
All Modes
Closed: The PID feedback level is too high.
All Modes
Closed: KEB Ride-Thru is being performed.
All Modes
Closed: A Fast Stop command has been entered from the operator or input terminals.
All Modes
Closed: oH pre-alarm time limit has passed.
All Modes
Closed: Internal cooling fan alarm
All Modes
Reserved for DWEZ digital output functions.
All Modes
Inverts the output switching of the multi-function output functions.
Set the last two digits of 1oo to reverse the output signal of that specific function.
All Modes
0: 0 to 10 V
1: -10 to 10 V
All Modes
Sets the function of terminal A1.
All Modes
Sets the level of the input value selected in H3-02 when 10 V is input at
terminal A1.
All Modes
Sets the level of the input value selected in H3-02 when 0 V is input at terminal
A1.
All Modes
0: 0 to 10 V
1: -10 to 10 V
All Modes
Sets the function of terminal A3.
All Modes
Sets the level of the input value selected in H3-06 when 10 V is input at
terminal A3.
All Modes
Sets the level of the input value selected in H3-06 when 0 V is input at terminal
A3.
YASKAWA ELECTRIC SIEP YEAHHP 01B YASKAWA AC Drive – A1000 HHP Programming Manual
Description
CLV
Description
Page
114
114
114
114
114
114
114
114
114
114
Values
Page
Default: 0
115
Range: 0, 1
Default: 0
115
Range: 0 to 31
Default: 100.0%
Min.: -999.9
115
Max.: 999.9
Default: 0.0%
Min.: -999.9
115
Max.: 999.9
Default: 0
116
Range: 0, 1
Default: 2
116
Range: 0 to 31
Default: 100.0%
Min.: -999.9
117
Max.: 999.9
Default: 0.0%
Min.: -999.9
117
Max.: 999.9