O: Operator-Related Settings; O: Operator-Related Settings; O1: Digital Operator Display Selection; O2: Digital Operator Keypad Functions - YASKAWA A1000 HHP Programming Manual

High performance vector control drive
Table of Contents

Advertisement

A.12 o: Operator-Related Settings
A.12 o: Operator-Related Settings
The o parameters set up the digital operator displays.
u

o1: Digital Operator Display Selection

No.
(Addr.
Name
Hex)
o1-01
Drive Mode Unit Monitor
(500)
Selection
o1-02
User Monitor Selection after
(501)
Power Up
o1-03
Digital Operator Display
(502)
Selection
o1-04
V/f Pattern Display Unit
(503)
o1-10
User-Set Display Units
(520)
Maximum Value
o1-11
User-Set Display Units
(521)
Decimal Display
<1> Default setting is dependent on parameter A1-02, Control Method Selection.
<2> Default setting is dependent on parameter o1-03, Digital Operator Display Selection.
u

o2: Digital Operator Keypad Functions

No.
(Addr.
Name
Hex)
o2-01
LO/RE Key Function
(505)
Selection
o2-02
STOP Key Function
(506)
Selection
o2-03
User Parameter Default
(507)
Value
o2-04
Drive Model Selection
(508)
292
All Modes
Selects the content of the last monitor that is shown when scrolling through
Drive Mode display. Enter the last three digits of the monitor parameter
number to be displayed: Uo-oo.
All Modes
1: Frequency reference (U1-01)
2: Direction
3: Output frequency (U1-02)
4: Output current (U1-03)
5: User-selected monitor (set by o1-01)
All Modes
Sets the units the drive should use to display the frequency reference and motor
speed monitors.
0: 0.01 Hz
1: 0.01% (100% = E1-04)
2: r/min (calculated using the number of motor poles setting in E2-04, E4-04,
or E5-04)
3: User-selected units (set by o1-10 and o1-11)
V/f
V/f w PG
OLV
OLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
0: Hz
1: r/min
All Modes
These settings define the display values when o1-03 is set to 3.
o1-10 sets the display value that is equal to the maximum output frequency.
o1-11 sets the position of the decimal position.
All Modes
0: Disabled
1: Enabled. LO/RE key switches between LOCAL and REMOTE operation.
All Modes
0: Disabled. STOP key is disabled in REMOTE operation.
1: Enabled. STOP key is always enabled.
All Modes
0: No change.
1: Set defaults. Saves parameter settings as default values for a User
Initialization.
2: Clear all. Clears the default settings that have been saved for a User
Initialization.
All Modes
Enter the drive model. Setting required only if installing a new control board.
YASKAWA ELECTRIC SIEP YEAHHP 01B YASKAWA AC Drive – A1000 HHP Programming Manual
Description
CLV
CLV
Description
Values
Page
Default: 106
(Monitor U1-06)
161
Range: 104 to 809
Default: 1
161
Range: 1 to 5
<1>
Default:
161
Range: 0 to 3
<1>
Default:
162
Range: 0, 1
<2>
Default:
162
Range: 1 to 60000
<2>
Default:
162
Range: 0 to 3
Values
Page
Default: 1
162
Range: 0, 1
Default: 1
163
Range: 0, 1
Default: 0
163
Range: 0 to 2
Default:
Determined by
163
drive capacity

Hide quick links: