F5: Digital Output Card (Do-A3); F6, F7: Communication Option Card - YASKAWA A1000 HHP Programming Manual

High performance vector control drive
Table of Contents

Advertisement

A.8 F: Options
No.
(Addr.
Name
Hex)
F4-03
Terminal V2 Monitor
(393)
Selection
F4-04
(394)
Terminal V2 Monitor Gain
F4-05
(395)
Terminal V1 Monitor Bias
F4-06
(396)
Terminal V2 Monitor Bias
F4-07
Terminal V1 Signal Level
(397)
F4-08
Terminal V2 Signal Level
(398)
u

F5: Digital Output Card (DO-A3)

No.
(Addr.
Name
Hex)
F5-01
Terminal P1-PC Output
(399)
Selection
F5-02
Terminal P2-PC Output
(39A)
Selection
F5-03
Terminal P3-PC Output
(39B)
Selection
F5-04
Terminal P4-PC Output
(39C)
Selection
F5-05
Terminal P5-PC Output
(39D)
Selection
F5-06
Terminal P6-PC Output
(39E)
Selection
F5-07
Terminal M1-M2 Output
(39F)
Selection
F5-08
Terminal M3-M4 Output
(3A0)
Selection
F5-09
DO-A3 Output Mode
(3A1)
Selection
u

F6, F7: Communication Option Card

Parameters F6-01 through F6-03 and F6-06 through F6-08 are used for CC-Link, CANopen, DeviceNet, PROFIBUS-DP, and
MECHATROLINK-II options. Other parameters in the F6 group are used for communication-protocol-specific settings. F7
parameters are used for EtherNet/IP, Modbus TCP/IP, and PROFINET options.
264
All Modes
Sets the monitor signal for output from terminal V2. Set this parameter to the
last three digits of the desired Uo-oo monitor. Some U parameters are
available only in certain control modes.
All Modes
Sets the gain for voltage output via terminal V2.
All Modes
Sets the amount of bias added to the voltage output via terminal V1.
All Modes
Sets the amount of bias added to the voltage output via terminal V2.
All Modes
0: 0 to 10 V
1: -10 to 10 V
All Modes
0: 0 to 10 V
1: -10 to 10 V
All Modes
Sets the function for contact output terminals M1-M2, M3-M4, and
photocoupler output terminals P1 through P6.
All Modes
0: Output terminals are each assigned separate output functions.
1: Binary code output.
2: Use output terminal functions selected by parameters F5-01 through F5-08.
YASKAWA ELECTRIC SIEP YEAHHP 01B YASKAWA AC Drive – A1000 HHP Programming Manual
Description
Description
Values
Page
Default: 103
88
Range: 000 to 999
Default: 50.0%
Min.: -999.9
88
Max.: 999.9
Default: 0.0%
Min.: -999.9
88
Max.: 999.9
Default: 0.0%
Min.: -999.9
88
Max.: 999.9
Default: 0
88
Range: 0, 1
Default: 0
88
Range: 0, 1
Values
Page
Default: 2
89
Range: 0 to 192
Default: 4
89
Range: 0 to 192
Default: 6
89
Range: 0 to 192
Default: 37
89
Range: 0 to 192
Default: F
89
Range: 0 to 192
Default: F
89
Range: 0 to 192
Default: 0
89
Range: 0 to 192
Default: 1
89
Range: 0 to 192
Default: 0
89
Range: 0 to 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents