F: Options; F: Options; F1: Pg Speed Control Card (Pg-X3/Pg-B3) - YASKAWA A1000 HHP Programming Manual

High performance vector control drive
Table of Contents

Advertisement

A.8 F: Options
F parameters program the drive for PG feedback from the motor and to function with option cards.
u

F1: PG Speed Control Card (PG-X3/PG-B3)

Parameters F1-01, F1-05, F1-06, F1-12, F1-20, F1-21 include "PG 1" in the parameter name and are used to set up a PG option
card plugged into option port CN5-C of the drive.
Parameters F1-21 through F1-37 include "PG 2" in the parameter name and are used to set up a PG option card plugged into
option port CN5-B of the drive.
Other parameters in the F1 group are used to set operation for PG options plugged into port CN5-C and CN5-B.
No.
(Addr.
Name
Hex)
F1-01
PG 1 Pulses Per Revolution
(380)
F1-02
Operation Selection at PG
(381)
Open Circuit (PGo)
F1-03
Operation Selection at
(382)
Overspeed (oS)
F1-04
Operation Selection at
(383)
Deviation
F1-05
PG 1 Rotation Selection
(384)
F1-06
PG 1 Division Rate for PG
(385)
Pulse Monitor
F1-08
Overspeed Detection Level
(387)
F1-09
Overspeed Detection Delay
(388)
Time
YASKAWA ELECTRIC SIEP YEAHHP 01B YASKAWA AC Drive – A1000 HHP Programming Manual
Description
V/f
V/f
V/f w PG
V/f w PG
V/f w PG
V/f w PG
OLV
OLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
CLV/PM
CLV/PM
Sets the number of PG (pulse generator or encoder) pulses. Sets the number
of pulses per motor revolution.
V/f
V/f
V/f w PG
V/f w PG
V/f w PG
V/f w PG
OLV
OLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
CLV/PM
CLV/PM
0: Ramp to stop. Decelerate to stop using the deceleration time in C1-02.
1: Coast to stop.
2: Fast Stop. Decelerate to stop using the deceleration time in C1-09.
3: Alarm only.
4: No alarm display
Note:
Due to potential damage to the motor and machinery, only use
the "Alarm only" and "No alarm display" settings under special
circumstances.
V/f
V/f
V/f w PG
V/f w PG
V/f w PG
V/f w PG
OLV
OLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
CLV/PM
CLV/PM
0: Ramp to stop. Decelerate to stop using the deceleration time in C1-02.
1: Coast to stop.
2: Fast Stop. Decelerate to stop using the deceleration time in C1-09.
3: Alarm only.
V/f
V/f
V/f w PG
V/f w PG
V/f w PG
V/f w PG
OLV
OLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
CLV/PM
CLV/PM
0: Ramp to stop. Decelerate to stop using the deceleration time in C1-02.
1: Coast to stop.
2: Fast Stop. Decelerate to stop using the deceleration time in C1-09.
3: Alarm only.
V/f
V/f
V/f w PG
V/f w PG
V/f w PG
V/f w PG
OLV
OLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
CLV/PM
CLV/PM
0: Pulse A leads
1: Pulse B leads
V/f
V/f
V/f w PG
V/f w PG
V/f w PG
V/f w PG
OLV
OLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
CLV/PM
CLV/PM
Sets the division ratio for the pulse monitor used of the PG option card installed
to port CN5-C.
By setting "xyz", the division ratio becomes = [(1 + x) / yz].
If only using the A pulse for one-track input, the input ratio will be 1:1
regardless of F1-06 setting.
V/f
V/f
V/f w PG
V/f w PG
V/f w PG
V/f w PG
OLV
OLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
CLV/PM
CLV/PM
Sets the overspeed detection level as a percentage of the maximum output
frequency.
V/f
V/f
V/f w PG
V/f w PG
V/f w PG
V/f w PG
OLV
OLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
CLV/PM
CLV/PM
Sets the time in seconds for an overspeed situation to trigger a fault (oS).
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
A.8 F: Options
Values
Page
Default: 1024 ppr
Min.: 1
84
Max.: 60000
Default: 1
84
Range: 0 to 4
Default: 1
84
Range: 0 to 3
Default: 3
85
Range: 0 to 3
<1>
Default:
85
Range: 0, 1
Default: 1
Min.: 1
85
Max.: 132
Default: 115%
Min.: 0
84
Max.: 120
<1>
Default:
84
Min.: 0.0 s
Max.: 2.0 s
261
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents