HP 1652B Getting Started Manual page 218

Logic
Hide thumbs Also See for 1652B:
Table of Contents

Advertisement

Not all sequence level pop-up menus look like this one. This happens
to be the trigger sequence level in which you specify the state on which
the analyzer is to trigger. The trigger term can occur in any of the first
seven levels, and it is not necessarily a selectable field The fields in the
menu of figure 10-8 are described on the following pages.
InSeti Level
To insert a level, place the cursor on the field labeled Insert Level and
press SELECT. You will see the following pop-up menu.
Figure
W-9.
Insert Level Pop-Up Menu
Cancel returns you to the sequence level pop-up without inserting a
level. Before inserts a level before the present level. Aflter inserts a level
after the present level. If there are eight levels, the Insert Level field
doesn't appear in the sequence level pop-ups.
Delete
Level
If you want to delete the present level, select the field labeled
Delete
Level. You will see a pop-up menu with the choices Cancel and
Execute. Cancel returns you to the sequence level pop-up without
deleting the level. Execute deletes the present level and returns you to
the State Trace Specification menu.
Note d
If h t ere are only two levels, neither field can be deleted even though the
Delete Level field stilI appears in the menu. There will always be's
trigger term level and a store term level in Sequence Levels. Therefore,
if you try to delete either of these, all terms you have specified in these
levels will be set to default terms, and, the trigger and store term levels
will remain.