HP 16528/16538
State Trace Menu
Front-Panel Reference
lo-17
Sequence
Levels
Hhile
storing
"b"
Then
find
"c"
1 times
Else on "f"
go to level
4
Hhile
storing
"d"
Then find
"c"
1 times
Hhile
storing
"8"
Then find
"g"
1 times
Figure 1042. Branching Between Sequence Levels
Each sequence level can branch to only one level through a secondary
branching qualifier. However, the number of times to which a level can
be branched is limited only by the number of levels present. A level can
have only one arrow pointing away from it, but it can have two pointing
to it if more than one other level is branching to it. An example of this
is shown in the figure below. The arrow with two tails indicates that a
level above and a level below branch to this level.
Sequence
Levels
Hhile
storing
" any state"
Find " any state"
1 times
Else
on "b" go
to
level
2
Hhlle
storing
" any state"
Then f lnd 'Id"
1 times
Else
on "g"
go to level
3
Hhlle
storing
" any state"
Trigger
on "a"
1 times
Else
on u any state"
go to level
2