statistics
The last field in the Markers
pop-up
shown
in figure 25-10 is Statistics.
When Statistics is selected from the Markers field, a new middle row of
fields appear. See figure 25-19.
HP 16528/1653B
Front-Panel Reference
jfcope]-
lbveforres
valid
runs'
2 01
7
narkers[Statistlcs
1
Dlsplsy
r-6Kr-j
Connect
dotsI]
Figure 25-19. Statistics Fields
The Statistics field allows you to make minimum, maximum, and mean
time interval measurements from marker X to marker 0.
Minimum, maximum, and mean (average) X-O marker time interval
data is accumulated and displayed until one of the following happens:
1. Autoscale is executed.
2. Auto-marker parameters are changed.
3. Statistics is set to Off.
4. Repetitive Run mode is stopped.
The default for the Min, Max, and Mean fields is 0 s.
Waveforms Menu
25-23