HP 1652B Getting Started Manual page 605

Logic
Hide thumbs Also See for 1652B:
Table of Contents

Advertisement

Clock, Qualifier,
Description:
and
Data
'nputs
Test 4
This test verifies the minimum
swing voltages of the input probes and the
maximum clock rate of the HP 1652B/1653B when it is in the single phase mode.
Specification:
Minimum
swing: 600 mV peak-to-peak.
Clock repetition
rate: Single phase is 35 MHz maximum (25 MHz maximum for
the HP 1653B).
Clock pulse width:
> 10 ns at threshold.
Equipment
Required:
Pulse Generator
.........
.' ................
HP
8161 A/O20
Oscilloscope
............................
HP 54502A
50 Ohm Feedthrough
(2) ...................
HP
IOlOOC
Test Connector
(2) .........................
see figure 3-1 and 3-2
BNC m-m Coupler (2) .....................
HP
1250-0216
BNC Cable (2) ...........................
HP
10503A
BNC Tee
m-f-f (2) .........................
HP 1250-0781
Procedure:
1. Connect the HP 1652B/1653B and test equipment as in figure 3-19. In order
to most accurately measure the amplitude
of the test signals from the pulse
generator, high impedance scope probes should be used to look at the signal
levels at the output of the pulse generator.
LOGIC
ANALYZER
Figure 3-19. Setup for Data Test 4
I
Note @
In this setup, only eight channels are tested at one time to minimize loading. The
ground lead must be connected to ensure accurate test results. It is recommended
that all eight channel grounds be connected.
-
Performance
Tests
HP 1652B/1653B
3-18
Service
Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

1653b

Table of Contents