HP 1652B Getting Started Manual page 620

Logic
Hide thumbs Also See for 1652B:
Table of Contents

Advertisement

-
5. Adjust the power supply output for + 150 mV.
6. Press RUN. Data displayed
on
the
Thing
Waveforms
display is all high for
the pod and channels under t&t as in figure 3-39.
-iI-
Timing
biavef ems
tlarkers
I-1
Accumulate
torrj
flme/Dlv
7100
Delay
11
Sample
period
-
20 ns
w
\
PoDij
,
,
I
I
I
:
Figure 3-39. Threshold
Accuracy
Timing
Waveforms
1
7. Adjust the power supply output for -150 mV.
8. Press RUN.
Data displayed
on
the
Timing Waveforms
display is all low for
the channels under test as in figure 3-40.
l-l-
Tlmlng
Wsvef arms
tlar ker9
1-1
CIccumula te
Iorrj
Time/D iv 11
Delay
IO]
Sample
period
-
20 ns
\
lpoDd
I
I
I
I
I
1
:
Figure 3-40. Threshold
Accuracy
Timing
Waveforms
2
9. Return to the
Timing
Format Specification
and change the
User Defined
pod threshold to + 9.9
V.
10. Adjust the power supply output for + 10.2 V.
11. Press RUN.
Data displayed
on Timing Waveforms
display is all high for the
pod and channels under test as in the previous figure 3-39.
HP 16528/1653B
Service Manual
Performance
Tests
3-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

1653b