1.2 INSTALLATION REQUIREMENTS

1.2.1 ENVIRONMENT

1.
Temperature Range: 10 °C to 32 °C (50 °F to 90 °F)
2.
Humidity Range: 15% to 80% RH
3.
Ambient Illumination: Less than 1,500 lux (do not expose to direct sunlight.)
4.
Ventilation: Room air should turn over at least 30 m
5.
Ambient Dust: Less than 0.10 mg/m
6.
Avoid areas exposed to sudden temperature changes:
Areas directly exposed to cool air from an air conditioner.
Areas directly exposed to heat from a heater.
7.
Do not place the machine where it will be exposed to corrosive gases.
8.
Do not install the machine at any location over 2,000 m (6,500 ft.) above sea level.
9.
Place the main machine on a strong and level base. Inclination on any side should be
no more than 5 mm (0.2").
10. Do not place the machine where it may be subjected to strong vibrations.

1.2.2 MACHINE LEVEL

Front to back: Within 5 mm (0.2") of level
Right to left: Within 5 mm (0.2") of level

1.2.3 MINIMUM SPACE REQUIREMENTS

Place the main machine near the power source, providing clearance as shown:
A: Front: >75 cm (29.6")
B: Left: > 10 cm (4")
C: Rear: > 10 cm (4")
D: Right > 10 cm (4")