Sets the length of time (seconds) for the time-out when sent data is written to the
RCG during a call over the NRS network.
[0~100/1 sec.]
RCG Read Timeout
010 Sets the length of time (seconds) for the timeout when sent data is written from the
RCG during a call over the NRS network.
[0~100/1 sec.]
Port 80 Enable
Controls if permission is given to get access to the SOAP method over Port 80 on
the NRS network.
011
[0~1/1]
0: No. Access denied
1: Yes. Access granted.
RCG – C Registed
021 This SP displays the Cumin installation end flag.
1: Installation completed
2: Installation not completed
RCG – C Registed Det
This SP displays the Cumin installation status.
022
0: Basil not registered
1: Basil registered
2: Device registered
Connect Type (N/M)
023 This SP displays and selects the Cumin connection method.
0: Internet connection
1: Dial-up connection
Cert. Expire Timing DFU
061
Proximity of the expiration of the certification.
062 Use Proxy
SM
RCG – C Registered Detail
5-39