Installation; Installation Requirements; Optimum Environmental Condition; Environments To Avoid - Ricoh PT3 Field Service Manual

Table of Contents

Advertisement

2. Installation

Installation Requirements

Carefully select the installation location because environmental conditions greatly affect machine
performance.

Optimum Environmental Condition

1. Temperature: 10 to 30°C (50 to 86 F)
2. Humidity: 20 to 90 %RH
3. Install the machine on a strong and level base. The machine must be level within 5mm (0.2") both
front to rear left to right.

Environments to Avoid

1. Locations exposed to direct sunlight or strong light (more than 1,500 lux).
2. Dusty areas
3. Areas containing corrosive gases.
4. Locations directly exposed to cool air from an air conditioner or reflected heat from a space heater.
(Sudden temperature changes from low to high or vice versa may cause condensation within the
machine.)

Power Connection

1. Securely connect the power cord to a power source.
2. Make sure that the wall outlet is near the machine and easily accessible.
3. Make sure the plug is firmly inserted in the outlet.
4. Avoid multi-wiring
5. Do not pinch the power cord.

Minimum Space Requirements

Place the machine near a power source, providing minimum clearance as shown below.
2
21

Advertisement

Table of Contents
loading

Table of Contents