5.5 OUTPUT CHECK
Motors keep turning in this mode regardless of upper or lower limit sensor signals.
To prevent mechanical or electrical damage, do not keep an electrical component
on for a long time.
Enter the SP mode and select SP5804.
1.
Press
together (for 5 seconds), release, then press [#Enter].
System Ver.1.00
1. Service
2.
Press
.
System Ver. 1.00
2. Engine
3.
Press [#Enter].
<Engine>
1. Feed
4.
Press
to display "5. Mode".
<Engine>
5. Mode
5.
Press [#Enter].
SP5024
mm/inch Display
6.
Press
repeatedly to display "Output Check".
SP5804 >>
Output Check
7.
Press [#Enter].
SP5804-001
1st.PaperFeedCl.
8.
Press
or
to display the item to check.
SP5804-027
Fuser Exit Motor
G147
5-102
SM