8
SHOCK ABSORBER, SWINGARM
8.21

Filling the damper with nitrogen

When the pressure gauge reaches the specified value, turn the Damper control
lever
to Pressure.
Guideline
0 bar
Oil is pumped into the damper.
The pressure gauge rises to the specified value.
3 bar
200268-10
When the pressure gauge reaches the specified value, turn the Damper
lever to Vacuum.
Guideline
3 bar
The pressure gauge falls to the specified value.
0 bar
When the pressure gauge reaches the specified value, operate the On/Off switch.
Guideline
200269-10
0 bar
The vacuum pump is switched off.
Slide O-ring
minus specified value).
Guideline
10 mm
Depth micrometer (T107S) (
Slide the floating piston into the reservoir to the shortened position using the spe-
cial tool.
201284-10
Info
The floating piston must be positioned at exactly this point when the rod
is fully extended; otherwise, damage will occur during compression of the
shock absorber.
Remove the special tool.
Remove adapter
Info
Hold the damper so that the filling port is at the highest point.
Remove the adapter.
Mount and tighten screw
Guideline
Filling port screw
201283-10
Screw in screw
Info
The piston rod is fully extended.
201282-10
to the end of the special tool by the specified value (distance
p. 238)
from connection
.
by approx. 2 rotations but do not tighten.
of the vacuum pump.
M10x1
14 Nm
(10.3 lbf ft)
50