8
SHOCK ABSORBER, SWINGARM
8.21
Filling the damper with nitrogen
–
When the pressure gauge reaches the specified value, turn the Damper control
lever
to Pressure.
4
Guideline
0 bar
Oil is pumped into the damper.
The pressure gauge rises to the specified value.
3 bar
200268-10
–
When the pressure gauge reaches the specified value, turn the Damper
lever to Vacuum.
Guideline
3 bar
The pressure gauge falls to the specified value.
0 bar
–
When the pressure gauge reaches the specified value, operate the On/Off switch.
Guideline
200269-10
0 bar
The vacuum pump is switched off.
–
Slide O-ring
minus specified value).
Guideline
10 mm
Depth micrometer (T107S) (
–
Slide the floating piston into the reservoir to the shortened position using the spe-
cial tool.
201284-10
Info
The floating piston must be positioned at exactly this point when the rod
is fully extended; otherwise, damage will occur during compression of the
shock absorber.
–
Remove the special tool.
–
Remove adapter
Info
Hold the damper so that the filling port is at the highest point.
–
Remove the adapter.
–
Mount and tighten screw
Guideline
Filling port screw
201283-10
–
Screw in screw
Info
The piston rod is fully extended.
201282-10
to the end of the special tool by the specified value (distance
B
p. 219)
from connection
of the vacuum pump.
1
2
.
9
by approx. 2 rotations but do not tighten.
1
M10x1
14 Nm
(10.3 lbf ft)
49
control
4
A