10. SERVICE MODE

10.5.11 Communication System Setting

Selects the communication system used at the RS-232C port.
A. Procedure
1.
"Service Mode screen"
Press [System 1].
2.
"System Input screen"
Press [Communication System Setting].
3.
"System Input screen"
• System Input ( [CS Remote Care] / [JScribe1] / [JScribe2] )
Selects the communication system used at the RS-232C port.
• JScribe ( [ON] / [OFF] )
When [JScribe1] or [JScribe2] is selected at System Input, set [JScribe] to ON.
When [CS Remote Care] is selected at System Input, set [JScribe] to OFF.
Communication specifications of each system are as follows:
Baud rate
Data bit
Parity bit
Stop bit
NOTE
Operating conditions when using JScribe are as follows:
• An optional hard disk and an image controller shall be equipped.
• System memory shall be added (Add-on memory : 128MB).
4.
Press [OK].
200
1
CS Remote Care
9,600 bps
8 bit
None
1 bit
Confidential – for internal use only, do not distribute
Field Service Ver.2.0 Jan. 2007
JScribe1
19,200 bps
7 bit
Odd
1 bit
JScribe2
19,200 bps
8 bit
None
1 bit