Field Service Ver.2.0 Jan. 2007
Classification
Code
Page
C-B185
control
C-B186
C-B187
C-B188
Operation
C-C103
panel
commu-
nication
abnor-
mality
Machine
C-C181
type
detection
abnor-
mality
Flash
C-C182
ROM
abnor-
mality
Software
C-C183
abnor-
mality
Non-
C-C284
volatile
memory
C-C285
abnor-
mality
C-C286
C-C287
C-C288
HDD
C-D001
C-D002
Confidential – for internal use only, do not distribute
Causes
Incoming data size logic error
(The incoming data is not a multi-
ple number of DotLine.
Image Buff acquisition (alloc) error
Error return from Compressor
Band Buff control error (new
Instance/get/free)
While in the completion of the
reception from the control of the
operation panel, either of the fol-
lowing is detected or after starting
the transmission, the transmis-
sion cannot be completed within
a specified period of time.
• Data checksum error
• Communication GA gener-
ates an error vector.
The machine type mentioned in
the software is different from the
machine type information given
on the main body drive board.
A flash ROM checksum error of
the image control board is
detected.
The machine type mentioned in
the software is different between
the overall control and the image
control.
Non-volatile memory abnormality
*1
Non-volatile memory abnormality
*1
Non-volatile memory abnormality
*1
Non-volatile memory abnormality
*1
Non-volatile memory abnormality
*1
HDD initialization abnormality.
JOB RAM retention abnormality.
13. MALFUNCTION CODE
Resulting
Estimated abnormal parts
operation
FAX breakdown
FK-502
Engine section
Overall control board (OACB)
power OFF.
It stops immedi-
Overall control board (OACB)
ately.
NVRAM board (NRB)
Engine section
HD-505
power OFF.
337