Software Sw Setting For Cs Remote Care - Konica Minolta bizhub 500 Service Manual

Hide thumbs Also See for bizhub 500:
Table of Contents

Advertisement

Field Service Ver.2.0 Jan. 2007

10.11.3 Software SW setting for CS Remote Care

Note
• SW bits data are written into the NVRAM every time a change is made. In case you changed bit
data by accident, be sure to restore the previous state.
A. Input procedure
1.
Select [Service Mode] → [CS Remote Care] → [Detail Setting], and touch [Software Switch Setting].
2.
Touch [Switch No.], and input the SW number (two digits) using the 10-Key Pad.
3.
Touch [Bit Assignment], and select SW bit number using the arrow keys, and input 0 or 1 using the 10-Key
Pad.
(For setting by hexadecimal numbers, touch [HEX Assignment] key, and input using the 10-Key Pad or A
to F keys.)
4.
Touch [Fix].
Note
• About functions of each switch, see to
B. List of software SW for CS Remote Care
Note
• Do not change any bit not described on this table.
SW No.
Bit
SW 01
0
1
2
3
4
5
6
7
SW 02
0
1
2
3
4
5
6
7
SW 03
0
1
2
3
4 to 7 Reservation
Confidential – for internal use only, do not distribute
"B. List of software SW for CS Remote
Functions
Dial Mode
Reservation
Reservation
Reservation
Baud rate
Emergency transmission
Auto call on date specification
Reservation
Reservation
Reservation
Auto call on the IC Life
Auto call on CCD Clamp/Gain
Adjustment failure
Reservation
Reservation
Auto call on the toner empty
Reservation
Auto call on the waste toner bottle full
10. SERVICE MODE
Care".
0
1
Pulse
Tone
*1
*1
*1
*1
*1
*1
*1
*1
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Default
1
0
0
0
0
0
0
1
1
1
0
0
0
1
1
0
0
1
0
1
0
251