Field Service Ver.1.0 Feb. 2006
2.1.2
Replacing the separation roller
A. Periodically replaced part/cycle
•
Separation rubber: Every 500,000 prints (Actual replacement cycle: Every 200,000 prints)
B. Procedure
[1]
[4]
[2]
Confidential – for internal use only, do not distribute
[2]
[3]
16aaf2c008na
[1]
16aaf2c009na
1.
Pull out LU from the main body.
2.
Open the upper door [1].
3.
Lift up the paper feed roller unit [2].
4.
Remove the 2 screws [3] and then remove the
guide plate [4].
5.
Remove the 2 screws [1] and then remove the left
cover [2].