3. PERIODIC CHECK
[1]
[2]
[4]
[3]
[7]
[6]
86
[5]
[8]
[1]
[6]
50gaf2c094na
Confidential – for internal use only, do not distribute
Field Service Ver.2.0 Jan. 2007
• The performance of a new fusing web [1] is
guaranteed from the position at which a
brown line [2] is broken. When replacing the
fusing web, be sure to take up the fusing web
up to the position at which the distance [5]
from the nip section [4] of the fusing roller [3]
and the fusing web to the brown line becomes
0 to 10 mm or less.
• When taking up the fusing web, be sure to
bring down the release lever [6] to release the
cleaner lock gear [7] and rotate the web drive
gear [8].
• When replacing the fusing web, be sure to
reset the fusing web counter in the service
mode.
(See P.210)
6.
Reinstall the above parts following the removal
step in reverse.