Removing/Reinstalling The Ccd Unit - Konica Minolta bizhub 500 Service Manual

Hide thumbs Also See for bizhub 500:
Table of Contents

Advertisement

6. OTHERS
6.3.13

Removing/reinstalling the CCD unit

A. Procedure
[2]
[1]
[4]
[3]
[4]
[1]
150
[5]
[4]
[6]
[7]
50gaf2c066na
[2]
50gaf2c065na
Confidential – for internal use only, do not distribute
Field Service Ver.2.0 Jan. 2007
1.
Remove the original glass.
(See P.145)
2.
Remove the 2 screws [1] and the remove the lens
light blocking cover assy [2].
3.
Remove the connector [3].
4.
Remove the 9 screws [4] and then remove the
lens light blocking cover [5].
5.
Remove the 3 screws [6] and then remove the rib-
bon cable cover [7].
Note
• Be careful not to damage the scanner wire.
6.
Remove the ribbon cable [2] from the CCD board
(CCDB) [1].

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 360Bizhub 420

Table of Contents