Type: Error
Event ID: 1001
Description: The IPMI device driver attempted to determine if the system supported an
IPMI BMC device. The driver attempted to detect the presence of the IPMI BMC by
searching the SMBIOS for Type 38 record. But either no record was found or the
record was not compatible with the version of the device driver.
If a SMBIOS Type 38 record was detected, the Dump Data field of the event contains a
binary representation of the record.
- If you use the "Hardware Management" feature provided by Windows Server
2003 R2, above-shown event log will be registered.

Problems with NEC ExpressBuilder

When the server does not boot from the NEC ExpressBuilder CD-ROM, check the
following:
■ Did you set the NEC ExpressBuilder during POST and restart the server?
- If you do not set the NEC ExpressBuilder during POST and restart the server,
an error message will appear or the OS will boot.
■ Is BIOS configuration correct?
- The boot device order may be specified with the CMOS Setup utility of the
server. Use the CMOS Setup utility to change the boot device order to boot the
system from the optical disc drive first.
<Menu to check: [Boot]>
■ Is an error message displayed?
- When an error occurs while the NEC ExpressBuilder is in progress, the follow-
ing message appears. After this message appears, check the error and take the
appropriate corrective action according to the message listed in the table below.
Message
This machine is not supported
Hard disk access error
NvRAM access error
The system-specific information does not exist
on the baseboard. Please restore the backup
data or write the data by using [System
Information Management] of the Off-line
Maintenance Utility. Only the authorized
personnel are allowed to do this operation.
Table 26: Error Messages
Cause and Solution
This NEC ExpressBuilder version is not
designed for this server. Execute the NEC
ExpressBuilder on the compliant server.
The hard disk is not connected or has failed.
Check whether the hard disk is correctly
connected.
An access to the non-volatile memory (NvRAM)
has failed.
The system-specific information can't be
acquired on the mother board.
200