To connect the power cord:
1. Plug the provided power cord into the power receptacle on the rear of the
server.
2. Plug the other end of the power cord into the wall outlet.
To connect the power cord from the server to an interruptive power supply (UPS), use
service outlets on the rear of the UPS.
The UPS service outlets are categorized into two groups: SWITCH OUT and UN-
SWITCH OUT. (They may be called "OUTPUT1" and "OUTPUT2".)
To control power supply with an application that controls the UPS, connect the power
cord to an SWITCH OUT outlet.
For constant power supply, connect the power cord to a UN-SWITCH OUT outlet.
(Connect the modem that is in service for 24 hours to this outlet.)
When the power cord from the server is connected to a UPS, change the BIOS setup of
the server to link with power supply from the UPS.
To power on the server from the UPS (Uninterruptible Power Supply), select [Server] -
[AC-LINK] - [Power On].
Change a parameter for "AC Link" under the Server menu of the BIOS setup utility.
Figure 33: Connecting the Power Cord
A
A UN-SWITCH OUT/Output 2
Figure 34: Uninterruptible Power Supply Outlets
B
B SWITCH OUT/Output 1
61
www.nec-computers.com