Feature
Boot Monitoring
Policy
Thermal Sensor
BMC IRQ
POST Error Pause
AC-LINK
Power On Delay
Time (Sec)
Platform Event
Filtering
Table 15: Server Menu (Continued)
Choices or
Description
Display Only
Retry 3 Times
Specifies what happens when a
time out is detected during boot
Retry Service Boot
monitoring.
Always Reset
When Retry 3 Times is
selected, the system is reset
after a time out occurence, and
tries 3 times to boot the OS.
When Retry Service Boot is
selected, the system is reset
after a time out occurence, and
tries 3 times to boot the OS.
The system then tries to boot
from the service partition (3
times).
When Always Reset is
selected, the system is reset
after the time out occurence,
and tries repeatedly to boot the
OS.
Disabled
Specifies whether the thermal
sensor monitoring function is
Enabled
enabled or not.
If a thermal error is detected
while this parameter is enabled,
the system stops at the end of
the POST.
Disabled
Determines the routing of the
BMC Interrupt.
IRQ 11
Disabled
Specifies whether the system
Enabled
waits for user intervention on
critical POST errors.
If no keyboard is connected to
the system, this option is
ignored and the system always
continues to bootup.
Stays Off
Sets the AC-LINK feature.
Last State
Determines the mode of
Power On
operation if a power loss
occurs.
0 - 255
Sets the power-on delay time
whithin a 0 to 255 seconds
range.
This parameter is valid when
"Power On " or "Last State" is
specified for AC Link.
Disabled
This item is meaningless when
Enabled
the notification feature of the
Remote Management Card is
enabled.