U220 Setting The Trial Functions - Kyocera TASKalfa 250ci Service Manual

Hide thumbs Also See for TASKalfa 250ci:
Table of Contents

Advertisement

Maintenance
item No.
Setting the trial functions
U220
Description
Enables the trial of USB functions by period limitation.
Purpose
To try USB activation functions.
Method
Press the start key.
Display
FUNCTION
TRIAL STATUS
COUPON COUNT
TIME LIMIT
TRIAL START
TRIAL STOP
Setting: [FUNCTION]
1. Select [FUNCTION].
2. Select the function using the +/- keys.
3. Press the start key. The setting is set.
[COUPON COUNT], [TIME LIMIT], [TRIAL START] and [TRIAL STOP] are displayed.
Method: [TRIAL START]
1. Select [TRIAL STRAT].
2. Press the start key.
Trial of the function selected with [FUNCTION] is started.
The display of [COUPON COUNT] decreases one. The display of [TIME LIMIT] will be the date of the
present date plus 30 days.
3. Turn the main power switch off and on.
Method: [TRIAL STOP]
1. Select [TRIAL STOP].
2. Press the start key.
Trial of the function selected with [FUNCTION] is stopped.
3. Turn the main power switch off and on.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Selecting trial functions
Displays the current setting (1: Under trial, 0: Not trial)
Displays remaining times
Displays the end term of the function under present trial
Starts the trial of the function selected with FUNCTION
Stops the trial of the function selected with FUNCTION